Price excl VAT in case of delivery in continental Europe.
Operating voltage: 230V 50Hz or 12-15V DC.
Max load per output: 16A 230V.
Built-in outputs (relays): 2.
Cons. 60mA (standby, no active relay), add 30mA per active relay.
Operating temp.: –20 to 50ºC.
Temp. sensing: –29 to +49°C.
HxLxD: 70x90x58mm.
Weight: 375g.
GSM: Dualband 900/1800 MHz.
Complies with the European R&TTE directive.
GSM Fixi is designed for indoor use only.
Send commands to GSM Fixi by SMS to remotely switch on or off the appliances or wall sockets connected to its 2 outputs: heating, hot water, lights, pumps, small servers, etc.
Remote control of 2 outputs (16A relays) and 1 temperature sensor.
Thermostatic regulation for frost protection (keeping the temperature between 4-6 degrees when a heater is controlled by output #1).
Timer control.
Temperature surveillance: you receive an SMS if it gets colder or warmer than you want.
Personal access code for protection.
Usable either in 12V DC or in 230V/50Hz environments for:
low-voltage control of electronic circuits, or
230V control of loads of up to 7200 watts (2*3600W, for fuse box installation by qualified technicians).
Installation as DIN module.
Optional extension GS-33 module adds 3 extra outputs.
Included: a GSM antenna and a temperature sensor (8 meter cable).
GSM Fixi requires a valid SIM card from a mobile phone operator.